- VisiSafe : for safe operation and maintenance work on circuits.
- Class-2 insulation : continuous safety for operators and unqualified personnel.
- VisiTrip : detects faulty Miniature Circuit-Breaker outgoers quickly and reduces intervention time.
- Add-on fully immune earth leakage protection devices : better continuity of service, especially in polluted environments and networks.
- Nominal current: 1 to 63 A
- Large choice of breaking capacities up to 100 kA and tripping curves: B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
- Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
- Suitable for isolation in accordance with industrial standard IEC 60947
- Operating voltage: up to 440 V AC, insulation voltage: 500 V
- Optional add-on earth leakage modules: iC60 Vigi,
- Optional auxiliaries: indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
Miniature Circuit Breakers View all products
Benefits
- The new reference in final distribution,
- Absolute safety of circuit protection with VisiSafe,
- Greater continuity of service with VisiTrip,
- Simple to choose with meaningful part numbers,
- Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
- Environmentally friendly with 100% recyclable & recoverable materials.
Applications
- Low-voltage final distributionProtection of electrical circuits in all industrial and commercial buildings,
- All applications, especially in polluted environments and networks,
- Motor circuit protection,
- DC current circuit protection.
- Operating voltage: 12...500Vcc
- Number of poles: 1P, 2P
- Compliance with standards: multistandard UL 1077, IEC 60947-2, E~60947-2, GB 14048.2
- Rating: 0.5 to 63 A
- Breaking capacities: 5 to 10 kA depending on the standard
- Tripping curve: C
- Suitable for isolation in accordance with industrial standards: IEC 60947
- Multiple possibilities of connecting: box lug, ring tongue terminal...
- Options for installation: terminal shield, rotary handle, padlocking, dividable mounting plate
- Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip
Benefits
- Multistandard: international offer available world-wide
- Reliability: guaranteed breaking of DC current for best anti-fire protection
- Productivity: common accessories and auxiliaries for C60 AC and C60 DC ranges
Applications
- Protection of electrical circuits with a DC supply
- Power supply: Industrial automations, auxiliary circuit for MV substations, battery charging and UPS, power system safety, telecommunications
- Transport: railway, electrical vehicle, navy
- Electricity generation: photovoltaic, wind, nuclear
- Rated current: 16 to 160 A
- 3 breaking performances: 16, 25 and 36 kA under 415 V
- Rated operational voltage: 500 V AC
- 3-and 4-pole version
- NA type switch version
- Fixed thermal trip unit
- Earth leakage protection by associated Vigi module (upstream or downstream rigid connections)
- Optional auxiliaries: position indication, tripping indication, shunt trip or undervoltage trip control, extended rotary control
- Compliance with standards IEC 60947-1-2-3
Benefits
Ready to install
Benefiting from all the simplicity of modular installation, the NG160 circuit-breaker combines the performance and robustness essential for tertiary and industrial installations.Applications
Protection in all tertiary and industrial buildings:
- Incoming protection in modular enclosures
- Outgoing protection in power switchboards
- VisiSafe: for safe operation and maintenance work on circuits.
- Class-2 insulation: continuous safety for operators and unqualified personnel.
- VisiTrip: detects faulty Miniature Circuit-Breaker outgoers quickly and reduces intervention time.
- Add-on fully immune earth leakage protection devices: better continuity of service, especially in polluted environments and networks.
- Nominal current: 1 to 63 A
- Large choice of breaking capacities up to 100 kA and tripping curves: B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
- Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
- Suitable for isolation in accordance with industrial standard IEC 60947
- Operating voltage: up to 440 V AC, insulation voltage: 500 V
- Optional add-on earth leakage modules: iC60 Vigi,
- Optional auxiliaries: indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
Benefits
- The new reference in final distribution,
- Absolute safety of circuit protection with VisiSafe,
- Greater continuity of service with VisiTrip,
- Simple to choose with meaningful part numbers,
- Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
- Environmentally friendly with 100% recyclable & recoverable materials.
Applications
- Low-voltage final distributionProtection of electrical circuits in all industrial and commercial buildings,
- All applications, especially in polluted environments and networks,
- Motor circuit protection,
- DC current circuit protection.
- Nominal current: 10 to 125 A
- Large choice of breaking capacities and tripping curves: B, C, D…
- Compliance with standards: IEC EN 60898 or IEC 60947-2 depending on the version, certified by national official authorities
- Suitable for isolation in accordance with industrial standards: IEC 60947
- Operating voltage: up to 440Vac, insulation voltage: 500V
- Optional add-on earth leakage modules: C120 Vigi
- Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
Benefits
Applications
- Nominal current: 10 to 125 A
- Large choice of breaking capacities and tripping curves: B, C, D...
- Compliance with standards: IEC 60947-2, certified by national official authorities
- Suitable for isolation in accordance with industrial standards: IEC 60947
- Operating voltage: up to 500 Vac, insulation voltage: 690 V
- Optional add-on earth leakage modules: Vigi NG125
- Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
Benefits
Applications
- Protection in all industrial and tertiary buildings:
- Incoming protection in modular enclosure
- Outgoers in power switchboards.
Състои се от:
- Миниатюрни автоматични прекъсвачи за защита от късо съединение и претоварване
- Дефектнотокови защити за защита на хората от поражения от електрически ток
- Автоматични прекъсвачи с вградена дефектнотокова защита
- Защити от пренапрежение
- Захранващи гребени и разпределителни табла за улеснен монтаж на всички устройства
- Катодни отводители за защита от пренапрежение
The main function of iK60N circuit breaker is to ensure protection of low voltage electrical installations. This range consists of circuit breakers
- rated 1 A to 63 A:
- complying with IEC/EN 60898-1.
- with instant aneous tripping curves type B or C
- poles 1P, 1P+N, 2P, 3P or 4P.
- High-quality miniature circuit breakers for commercial and industry applications
- Contact position indicator red - green
- Accessories suitable for subsequent installation
- Rated currents up to 125 A
- Tripping characteristics B, C, D
- Rated breaking capacity up to 25 kA according to EN 60947-2
- High-quality miniature circuit breakers for DC-applications
- Contact position indicator red - green
- Guide for secure terminal connection
- 3-position DIN rail clip, permits removal from existing busbar system
- Comprehensive range of accessories suitable for subsequent installation
- Rated currents up to 50 A
- Tripping characteristic C
- Rated breaking capacity 10 kA according to IEC/EN 60947-2
- Up to 250 V DC per pole
- High-quality miniature circuit breakers for commercial and residential applications
- Contact position indicator red - green • Guide for secure terminal connection
- 3-position DIN rail clip, permits removal from existing busbar system
- Comprehensive range of accessories suitable for subsequent installation
- Rated currents up to 63 A
- Tripping characteristics B, C, D
- Rated breaking capacity 10 kA according to IEC/EN 60898-1
- High-quality miniature circuit breakers for commercial and residential applications
- Contact position indicator red - green
- Guide for secure terminal connection
- 3-position DIN rail clip, permits removal from existing busbar system
- Comprehensive range of accessories suitable for subsequent installation
- Rated currents up to 63 A
- Tripping characteristics B, C, D
- Rated breaking capacity 6 kA according to IEC/EN 60898-1
- High-quality miniature circuit breakers for commercial and residential applications
- Contact position indicator red - green
- Guide for secure terminal connection
- 3-position DIN rail clip, permits removal from existing busbar system
- Comprehensive range of accessories suitable for subsequent installation
- Rated currents up to 63 A
- Tripping characteristics B, C
- Rated breaking capacity 4.5 kA according to IEC/EN 60898-1
- High-quality miniature circuit breakers for commercial and industry applications
- Contact position indicator red - green
- Accessories suitable for subsequent installation
- Rated currents up to 63 A
- Tripping characteristics B, C
- Rated breaking capacity up to 6 kA according to EN 60947-2