Residual Current Circuit Breakers with Over Current Protection View all products
- Nominal current: 16A to 40A
- Tripping Curve: C
- 30mA sensitivity: additional protection against direct contact (in accordance with IEC 364)
- 300mA sensitivities: additional protection against fire and indirect contact (in accordance with IEC 364)
- Class AC - for normal installation
- Class Si (New) - for electrically disturbed networks (with harmonics, pulsating DC components etc.) & for harsh environments (presence of corrosive atmosphere, chemical gases, humid location etc)
- Conforms to IEC/EN 61009-1
- CE marked
- Suitable for additional Protection and Indication auxiliaries: ON/OFF, Trip, Shunt trip, Undervoltage trip, Overvoltage trip, Communication Auxiliar
- Compact 2poles 2module version
- Easy monitoring: Earth fault indication on front face
- Immunity against nuisance tripping
- New SI RCDs offers enhanced immunity to electrical disturbances and polluted & corrosive environments
- Ensures no accidental contact with live part – Finger-proof IP-20 terminals
- Avoids false insertion of cables and loose termination with Pull up terminals
- Environmentally friendly with 100% recyclable & recoverable materials.
Applications
- Protection in all industrial and commercial buildings against:Electrocution (in accordance with installation standard IEC 60364 and national standards)
- The risk of fire due to current leakage into building electrical installations.
- Protection of wires and cables against Overload and Short Circuit current fault.
- Nominal current: 6 to 40 A
- Compliance with standards: IEC EN 60898 and IEC EN 61009, certified by national official authorities
- Large selection of breaking capacities and tripping curves: B, C, D…
- Suitable for isolation in accordance with industrial standards: IEC 60947
- Operating voltage: up to 230 Vac
- 30mA sensitivity: additional protection against direct contact (in accordance with IEC 364)
- 100, 300, 500 mAsensitivities: additional protection against fire and indirect contact (in accordance with IEC 364)
- Type "si": protection of sensitive circuits (computing equipment) and those prone to disturbances (ballast lighting, power electronics)
- Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip.
Protection, in all industrial and tertiary buildings, against:
- faults on electrical circuits
- electrocution (in accordance with installation standards IEC 364 and national standards)
- the risk of fire due to leakage currents into building materials
Residual Current Circuit Breakers with Over Current Protection PFL6
- - A combination of residual current device / miniature circuit breaker
- - Nominal breaking capacity : 4.5 kA
- - Characteristics of the exclusion of MAP : B, C
- - Nominal current 30 mA
- - Rated current contacts up to 40 A
- - Sensitivity type : AC
- - Indication on / off ( red / green)
- - Free choice of party for inclusion in the network ( top or bottom )
Residual Current Circuit Breakers with Over Current Protection PFL6
- - Economy series mainly for building installations
- - A combination of residual current device / miniature circuit breaker
- - Characteristics of the circuit breaker : B, C
- - Rated breaking capacity : 6 kA
- - Rated current contacts up to 40 A
- - Nominal leakage current - 30 mA
- - Indicator on / off
- - Possibility of mounting accessories
- - Cold resistance - to -25º
Residual Current Circuit Breakers with Over Current Protection PFL7
- - A combination of residual current device / miniature circuit breaker
- Characteristics of exclusion: B, C
- Nominal breaking capacity - 10 kA Rated current contacts up to 40 A
- Nominal leakage current - 30 mA
- Indicator on / off
- Guide for secured connecting terminals
- 3-position clip allowing removed from the bus without having to dismantle the power comb
- Possibility of mounting accessories
- Cold resistance to -25º